Conrad CE-1877032 Handleiding


Bekijk gratis de handleiding van Conrad CE-1877032 (9 pagina’s), behorend tot de categorie Radiografisch bestuurbaar speelgoed. Deze gids werd als nuttig beoordeeld door 20 mensen en kreeg gemiddeld 4.0 sterren uit 3 reviews. Heb je een vraag over Conrad CE-1877032 of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/9
Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau
Item no.: 1877032
Material Safety Data Sheet
1. Product & Company Identification
Product: Lithium Polymer Rechargeable Battery
Manufacturer: Conrad Electronic SE
Nominal voltage: 7.4 V
Nominal capacity:3000 mAh, 22.2 Wh
Telephone: +49 (0) 9604 / 40 - 8988
Date of issue:10.12.2018
2. Hazards Identification
Preparation hazards and classification
Not dangerous with normal use. Do not dismantle, open or shred LITHIUM POLYMER CELL the ingredients contained within
or their ingredients products could be harmful.
Appearance, Color, Odor
Solid object with no odor, no color.
Primary Route(s) of Exposure
These chemicals are contained in a sealed stainless steel enclosure. Risk of exposure occurs only if the cell is mechanically,
thermally or electrically abused to the point of compromising the enclosure. If this occurs, exposure to the electrolyte solution
contained within can occur by Inhalation, Ingestion, Eye contact and Skin contact
Potential Health Effects:
ACUTE (short term): see Section 8 for exposure controls In the event that this battery has been ruptured, the electrolyte
solution contained within the battery would corrosive and can cause burns.
Inhalation: Inhalation of materials from a sealed battery is not an expected route of exposure. Vapors or mists from a ruptured
battery may cause respiratory irritation.
Ingestion: Swallowing of materials from a sealed battery is not an expected route of exposure. Vapors or mists from a ruptured
battery may cause respiratory irritation.
Ingestion: Swallowing of materials from a sealed battery is not an expected route of exposure. Swallowing the contents of an
open battery can cause serious chemical burns of mouth, esophagus, and gastrointestinal tract.
Skin: Contact between the battery and skin will not cause any harm. Skin contact with contents of an open battery can cause
severe irritation or burns to the skin.
Eye: Contact between the battery and the eye will not cause any harm. Eye contact with contents of an open battery can cause
severe irritation or burns to the eye.
CHRONIC (long term): see Section 11 for additional toxicological data
Medical Conditions Aggravated by Exposure
Not applicable
Reported as Carcinogen
Not applicable
Page 1 of 9

Beoordeel deze handleiding

4.0/5 (3 Beoordelingen)

Product specificaties

Merk: Conrad
Categorie: Radiografisch bestuurbaar speelgoed
Model: CE-1877032
Gewicht: 182 g
Breedte: 44 mm
Hoogte: 17 mm
Soort: Radio-Controlled (RC) Model Accessories & Supplies
Capaciteit van de accu/batterij: 3000 mAh
Accu/Batterij voltage: 7.4 V
Aantal per verpakking: 1 stuk(s)
Lengte: 136 mm
Type product: Batterij/Accu
Batterijtechnologie: Lithium-Polymeer (LiPo)
Aantal batterijcellen: 2

Heb je hulp nodig?

Als je hulp nodig hebt met Conrad CE-1877032 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Radiografisch bestuurbaar speelgoed Conrad

Handleiding Radiografisch bestuurbaar speelgoed

Nieuwste handleidingen voor Radiografisch bestuurbaar speelgoed