I N S T A L L A T I O N I N S T R U C T I O N S
WITH TS118 WITH TS218
THINSTALLâ„¢ IN-WALL ENCLOSURE
Spanish Product Description
German Product Description
Portuguese Product Description
Italian Product Description
Dutch Product Description
French Product Description
TA502
TA502 Installation Instructions
2
DISCLAIMER
Milestone AV Technologies, and its affiliated corporations and
subsidiaries (collectively, "Milestone"), intend to make this
manual accurate and complete. However, Milestone makes no
claim that the information contained herein covers all details,
conditions or variations, nor does it provide for every possible
contingency in connection with the installation or use of this
product. The information contained in this document is subject
to change without notice or obligation of any kind. Milestone
makes no representation of warranty, expressed or implied,
regarding the information contained herein. Milestone assumes
no responsibility for accuracy, completeness or sufficiency of
the information contained in this document.
Chief® is a trademark of Milestone AV Technologies.
All rights reserved.
IMPORTANT SAFETY INSTRUCTIONS!
WARNING: A WARNING alerts you to the possibility of
serious injury or death if you do not follow the instructions.
CAUTION: A CAUTION alerts you to the possibility of
damage or destruction of equipment if you do not follow the
corresponding instructions.
WARNING: Failure to read, thoroughly understand, and
follow all instructions can result in serious personal injury,
damage to equipment, or voiding of factory warranty! It is the
installer’s responsibility to make sure all components are
properly assembled and installed using the instructions
provided.
WARNING: Failure to provide adequate structural strength
for this component can result in serious personal injury or
damage to equipment! It is the installer’s responsibility to
make sure the structure to which this component is attached
can support five times the combined weight of all equipment.
Reinforce the structure as required before installing the
component. The wall to which the mount is being attached
may have a maximum drywall thickness of 5/8" (1.6cm).
WARNING: Exceeding the weight capacity can result in
serious personal injury or damage to equipment! It is the
installer’s responsibility to make sure the structure to which
this accessory is attached can support the combined weight
of the box and all equipment not to exceed 75 lbs (34.0 kg).
The combined weight of all components attached to the
TS118SU mount cannot exceed 35 lbs (15.9 kg). The
combined weight of all components attached to the TS218SU
mount cannot exceed 75 lbs (34.0 kg).
WARNING: Use this mounting system only for its intended
use as described in these instructions. Do not use
attachments not recommended by the manufacturer.
WARNING: Never operate this mounting system if it is
damaged. Return the mounting system to a service center for
examination and repair.
WARNING: Do not use this product outdoors.
NOTES:
• SUITABLE FOR USE IN OTHER
ENVIRONMENTAL AIR SPACE IN
ACCORDANCE WITH SECTION 300.22, (C)
OF THE NATIONAL ELECTRICAL CODE.
• The equipment shall be installed and
assembled by qualified service personnel.
• The maximum specified ambient temperature
of the cabinet system is 40° - 120°F (4° - 49°).
• Minimum spacings between the accessories
and components and the housing for
Information Technology Communication
Equipment shall be maintained for safe
operation of the equipment when installed in
accordance with the National Electric Code,
ANSI/NFPA 70-1999. Refer to communication
equipment manufacturer’s specifications for
minimum spacings.
• This Cabinet System is for use with Listed wall
mounts. Refer to the individual mount’s
installation instructions for compatibility.
--SAVE THESE INSTRUCTIONS--
Installation Instructions TA502
3
DIMENSIONS
LEGEND
18.85
478.8
GROUNDING
GROUNDING
TRIM NOT SHOWN
(USE THESE DIMENSIONS FOR CUTOUT)
NOTES:
ELECTRICAL KNOCK OUTS:
1.
SINGLE GANG RACO 590.• STEEL CITY CY 1/2, OR
SIMILAR STYLE ELECTRICAL
BOX.
1" AND 2" TRADE PIPE CONDUIT.•
PRODUCT WORKS WITH TS118 AND TS218.
2.
DIMENSIONS: INCHES
[MILLIMETERS]
Tighten Fastener
Apretar elemento de fijación
Befestigungsteil festziehen
Apertar fixador
Serrare il fissaggio
Bevestiging vastdraaien
Serrez les fixations
Loosen Fastener
Aflojar elemento de fijación
Befestigungsteil lösen
Desapertar fixador
Allentare il fissaggio
Bevestiging losdraaien
Desserrez les fixations
Phillips Screwdriver
Destornillador Phillips
Kreuzschlitzschraubendreher
Chave de fendas Phillips
Cacciavite a stella
Kruiskopschroevendraaier
Tournevis à pointe cruciforme
Pencil Mark
Marcar con lápiz
Stiftmarkierung
Marcar com lápis
Segno a matita
Potloodmerkteken
Marquage au crayon
Drill Hole
Perforar
Bohrloch
Fazer furo
Praticare un foro
Gat boren
Percez un trou
Hex-Head Wrench
Llave de cabeza hexagonal
Sechskantschlüssel
Chave de cabeça sextavada
Chiave esagonale
Zeskantsleutel
Clé à tête hexagonale


Product specificaties

Merk: Chief
Categorie: Flat panel steun
Model: TA502
Kleur van het product: Zwart
Breedte: 362 mm
Diepte: 101 mm
Hoogte: 437 mm
Maximale gewichtscapaciteit: 34 kg
Compatibiliteit: TS218SU, TS118SU