Cecilware Pro CE-G48TPF Handleiding

Cecilware Grillplaat Pro CE-G48TPF

Lees hieronder de 📖 handleiding in het Nederlandse voor Cecilware Pro CE-G48TPF (8 pagina's) in de categorie Grillplaat. Deze handleiding was nuttig voor 34 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/8
Thermostatic Gas Griddle
Operator Manual
Grindmaster-Cecilware
4003 Collins Lane, Louisville, KY 40245 USA
Phone: 502.425.4776 Toll Free: 800.695.4500
Fax: 502.425.4664
Web: gmcw.com Email: info@gmcw.com
Safety Information...........................................2
Specifications....................................................3
Installation........................................................4
Adjustments .....................................................6
Lighting Instructions (Thermostat Control)....6
Preparing Griddle.............................................6
Operation .........................................................6
Cleaning............................................................7
Maintenance ....................................................7
Troubleshooting...............................................8
Parts Diagram and List.....................................8
Thank you for purchasing this quality Gas Griddle. For your safety and the safety of others, read all
warnings and the operator’s manual before installing or using the product. Properly instruct all operators.
Keep training records. For future reference, record serial number here:
Table of Contents
Grindmaster-Cecilware provides the
industrys BEST warranty. Visit gmcw.com
for warranty terms and conditions.
Model: CE-G24TPF
CE-G15TPF, CE-G24TPF, CE-G36TPF, CE-G48TPF
©2016 Grindmaster-Cecilware
Printed in USA
0416 Form # CW-334-01
Part # 390-00081
2 Cecilware Pro®Thermostatic Gas Griddle
Safety Information
Important Safety Information
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages
that follow this symbol to avoid possible injury or death.
WARNING
Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury,
or death. Read the installation, operating, and maintenance instructions thoroughly before installing or
servicing this equipment.
Do not store or use gasoline or other ammable vapors or liquids in the vicinity of this or any other
appliance.
You must post instructions in a prominent location to be followed in the event the user smells gas. This
information shall be obtained by consulting the local gas supplier.
If you smell gas, close the shut-off valve, open windows, ventilate, and evacuate the area immediately. Do
not touch electrical switches or plugs. Extinguish any open flames. Immediately call your gas supplier.
Unit should only be used in a flat, level position.
Failure to install, adjust, or maintain this equipment properly can result in injury or death.
Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury,
or death. This installation must conform with local codes, with the National Fuel Gas Code, ANSI Z223.1
(latest edition), , or the Natural Gas Installation Code, CAN/CGA - B149.1 Propane Installation Code, CAN/CGA
- B149.2 as applicable. Have this equipment installed and adjusted by a qualified technician in accordance
with federal, state, and local codes.
Do not place anything over the flue opening.
Do not place combustibles or non-combustible material in the vicinity of the unit as this could cause fires or
obstruct air flow to the burner(s).
The unit must be disconnected from the gas supply during pressure testing of pipelines in excess of 1/2 psig
and isolated, by turning of the manual gas shut-off valve, during any testing equal to or less than 1/2 psig.
A qualified service technician must handle all maintenance and repair.
FAILURE TO COMPLY WITH THE ABOVE RISKS PERSONAL INJURY, SHOCK HAZARD, FIRE, OR DAMAGE TO
EQUIPMENT.
CAUTION
Read and understand the operating instructions in this manual thoroughly. Only allow properly trained
persons to operate this machine.
Stay alert at all times during operation.
This unit must be installed under a ventilation hood.
Allow unit to cool before cleaning or moving.
Do not leave appliance unattended with main gas valve open.
Do not use an open flame to check for leaks. Check all gas piping for leaks with a soap and water solution
before operating unit.
For your safety and the safety of others, read all warnings and the operator manual before installing or using the
product.
DANGER: This term warns the user of imminent hazard that will result in serious injury or death.
WARNING: This term refers to a potential hazard or unsafe practice, which could result in serious injury or
death.
CAUTION: This term refers to a potential hazard or unsafe practice, which could result in minor or moderate
injury.
NOTICE: This term refers to information that needs special attention or must be fully understood.
Thermostatic Gas Griddle Cecilware Pro®3
Safety Information (continued)
NOTICE
These models are designed, built, and sold for commercial use only.
Keep operating area clean.
Before using this equipment, it must be cleaned thoroughly. Failure to clean surfaces before using the unit
could cause food contamination and excessive smoking. Clean all surfaces before use.
Do not spray controls or outside of unit with liquids or cleaning agents.
Smoke appearing on initial use of the appliance is normal. This is a result of the rust-preventing coating
burning off. Allow the unit to “burn in” for at least 30 minutes before first use.
This unit is intended to be used to as a cooking
appliance in commercial foodservice operations only. It
is not intended for household use.
If you have questions concerning the installation,
operation, maintenance or service of this product,
contact your authorized service agent.
THESE UNITS ARE SUITABLE FOR INSTALLATION ON
NON-COMBUSTIBLE SURFACES ONLY.
Noncombustible and unit clearances: 6" sides (152 mm)
6" rear (152 mm) 4" countertop (102 mm)
There must be adequate clearance for removal of the
front panel. All major parts except the burners are
removable through the front if the gas line is
disconnected.
Do not obstruct the ow of combustion and ventilation
air, under the unit near the legs or behind the unit near
the ue. The space between the legs at the bottom
admits combustion air. DO NOT BLOCK THIS SPACE. Do
not place objects between the bottom of the unit and
the counter top.
If equipped, the vent line from the gas appliance
pressure regulator shall be installed to the outdoors in
accordance with local codes or, in the absence of local
codes, with the National Fuel Gas Code, ANSI
Z223.1/NFPA 54 Natural Gas and Propane, or the
Installation Code, CSA B149.1, as applicable.
Installation must conform with local codes, or in the
absence of local codes, with the National Fuel Gas Code,
ANSI Z223.1/NFPA 54, Liquefied Petroleum Gas Code
ANSI/NFPA 58, CSA-B149.1 Propane Installation, or the
Code, CSA-B149.2 as applicable and in accordance with
local codes.
The appliance and its individual shutoff valve
(to be supplied by user) must be disconnected from the
gas supply piping system during any pressure testing of
that system at test pressures in excess of ½ psi (3.5 kPa).
The appliance must be isolated from the gas
supply piping system by closing its individual manual
shut-off valve during any pressure testing of the gas
supply piping system at test pressures equal to or less
than ½ psi (3.5 kPa).
Do not permit fans to blow directly at the unit.
Wherever possible, avoid open windows next to the
units' sides or back. Avoid wall type fans, which create
air crosscurrents within a room.
It is also necessary that sufficient air should be allowed
to enter the room to compensate for air removed by
any ventilating system. Otherwise, an abnormal
atmospheric pressure will occur, affecting operation and
causing undesirable working conditions.
A properly designed and installed hood will act as the
ventilating system for the room or area in which the
unit is installed. For more information about air flow
and venting, please read NFPA 96: Standard for
Ventilation Control and Fire Protection of Commercial
Cooking Operations
Specifications


Product specificaties

Merk: Cecilware
Categorie: Grillplaat
Model: Pro CE-G48TPF

Heb je hulp nodig?

Als je hulp nodig hebt met Cecilware Pro CE-G48TPF stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Grillplaat Cecilware

Handleiding Grillplaat

Nieuwste handleidingen voor Grillplaat