KC41andKC42FittingInstructions
FAILURETOFOLLOWTHESEINSTRUCTIONSCANLEADTOPREMATUREPRODUCTFAILURE.
TheCDAGroupLtdcannotbeheldresponsibleforinjuriesorlossescausedbyincorrectuseor
installationofthisproduct.PleasenotethatCDAreservetherighttoinvalidatetheguarantee
suppliedwiththisproductfollowingincorrectinstallationormisuseoftheapplianceoruseina
commercialenvironment.
OverMounting
1.Placethepapertemplateprovidedcarefullyintothecorrectpositionontheworktop.
3.Useclearsiliconetosealthecutthathasbeenmade;liberallyspreadthesiliconeontothe
areaoftheworktopdirectlyadjacenttotheholeyouhavemadetothewidthofthesinkrim
thatitwillcomeintocontactwith.
4.Repeatstep3ontheundersideofthesinkrimitselfonthesurfacethatwillcomeinto
contactwiththeworktop.
5.Carefullypositionsothatyouavoidunnecessaryreadjustmentofthesinkatthemomentof
contact.
6.Pressdownfirmlyandholdinpositionforatleast5minutesapplyinganevenpressure.
7.Ensurethesinkisfullysealedandthejointiswaterproofbysqueezingresidualsiliconeout
fromalongthelineofthejoint.
8.Donotusethesinkforatleast24hoursoncefitted.
9.After24hourschecktoensurethesealiswaterproof.
UnderMounting
1.Placethepapertemplateprovidedcarefullyintothecorrectpositionontheworktop.
2.Cutalongtheundermountlineuntilthecentralsectionoftheworktopcomesout.
3.Finishtheworktopcutoutedgetothedesiredstandard.
4.Turntheworktopupsidedownonaflat,stablesurface.Notethiswillneedtobeleftin
positionfor24hours.
5.Spreadclearsiliconeliberallyontheglazedsurfaceontherimofthesinkensuringnoareas
areleftuncovered.
6.Spreadclearsiliconeliberallyontheundersideoftheworktoptothecorrespondingarea
wheretherimofthesinkwillbeincontact.
7.Pressthesinkdownintotherequiredpositionfirmlyforatleast5minutesapplyingeven
pressure.Positionaweightonthesinktokeepitinplace.
8.Ensurethesinkisfullysealedandthejointiswaterproofbysqueezingresidualsiliconeout
fromalongthelineofthejoint.
9.Donotusethesinkforatleast24hours.
10.3metalbracketsareprovidedwhichshouldbefixedalongthefrontedgeandoneoneach
side;theedgeofthebracketoverlapsthesinkrimandtheotheredgefixestotheworktop.If
astone/graniteworktopisbeingusedwoodenblockscanbeusedtoaffixtheclipstosecure
thesink;theseshouldbefixedwithanepoxy-typeadhesive(followmanufacturers’
instructionsforEpoxyadhesiveuse).