Page 1
WARNING
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code au-
thorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. To reduce the risk of fire, use only metal ductwork.
8. Do not install this product with the activating switch directly
behind a burner or element. Minimum distance between the
switch and the edge of the burner should be 4 inches.
9. Loose-fitting or hanging clothing should never be worn when
operating this appliance. They may be ignited by burners/
elements on cooktop.
10.Children should not be left alone or unattended in the area
where this appliance is in use.
11. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spillovers that may
ignite. Heat oils slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when
cooking flaming foods.
c) Clean ventilating fans frequently. Grease should not be
allowed to accumulate on fan or filter.
d) Use proper pan size. Always use cookware appropriate
for the size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE
EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE
FOLLOWINGa:
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet,
or metal tray, then turn off the burner. BE CAREFUL TO
PREVENT BURNS. If the flames do not go out immedi
ately, EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN - You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels
- a violent steam explosion will result.
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher, and you
already know how to operate it.
B. The fire is small and contained in the area where it
started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
a Based on “Kitchen Firesafety Tips” published by NFPA.
CAUTION
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. Clean filters and grease-laden surfaces frequently.
4. Do not repair or replace any part of this appliance unless
specifically recommended in this manual. All other servicing
should be done by a qualified technician.
5. Please read specification label on product for further informa-
tion and requirements.
MODEL WIDTH BLOWER
RMDD3004 30" 500 cfm Interior
RMDD3604 36" 500 cfm Interior
RMDD4804 48" 500 cfm Interior
RMDD3004EX 30" Models 331H, 332H, 335, or 336 Exterior (purchase separately)
RMDD3604EX 36" Models 331H, 332H, 335, or 336 Exterior (purchase separately)
RMDD4804EX 48" Models 331H, 332H, 335, or 336 Exterior (purchase separately)
WARNING - To reduce the risk of burns or ignition of clothing by reaching across burners, the downdraft remote control MUST
be mounted in the countertop - at least 4" from the burners. See "INSTALL COOKTOP" section on page 8.
!
INSTALLER:
Save this manual for Electrical
Inspector and Homeowner to use.
NOTE:
Model RMDDRBK Remote Up/Down
Control sold separately.
Page 2
Downdraft Ventilators
AIR
VENT
COUNTER
TOP
BLOWER
BOX
CHIMNEY TOP
COOK TOP
GEAR
MOTOR
COVER
TYPICAL INSTALLATION
120 VAC
GROUNDED
OUTLET
This downdraft blower system
is designed to be used to ex-
haust airborne contaminants
when cooking with a variety of
gas or electric cooktops. It can
be mounted in island, penin-
sula, or conventional wall loca-
tions.
This unit can be easily installed
following these basic steps:
Cut out the countertop
opening.
Mount the unit in the
cabinet.
Connect the ductwork and
electrical.
Install the cooktop.
Note: the high level of air flow of
this appliance may effect the
gas flame on some types of gas
cooktops. This is NORMAL and
will cause no harm, but can be
corrected by lowering the speed
of the blower.
PLANNING
Interior Blower Installation Exterior Blower Installation
Note: the high level of air flow of this appliance may effect the gas
flame on some types of gas cooktops. This is NORMAL and will
cause no harm, but can be corrected by lowering the speed of the
blower.
ELECTRICAL
SPECIFICATIONS
120 VAC • 60 Hz • 4.0 A
TAKE MEASUREMENTS
All Units
1. Refer to the cooktop installation instructions for dimensions of
cooktop, countertop cut-out, and cabinet requirements. Mod-
els RMDD3004 & RMDD3004EX will fit in most 30" wide
cabinets. Models RMDD3604 & RMDD3604EX will fit in most
36" wide cabinets. Models RMDD4804 & RMDD4804EX will
fit in most 48" wide cabinets. However, it is recommended that
oversized cabinets be used for easier installation.
2. Cooktop depth can vary greatly from one to another. This may
cause the fit of these two appliances to be rather tight.
Pay special attention to the areas of potential interference high-
lighted above. A countertop with (A) a raised lip and/or (B) a
backsplash may not allow enough flat countertop for a proper
installation. Note that 2" of flat countertop is required behind
cooktop and that 1-3/4" is necessary between the back edge of
the cooktop and the inside of cabinet back.
ELECTRICAL
SPECIFICATIONS
120 VAC • 60 Hz • 6.0 A (max.)
3-1/4" X 10"
DUCT CONNECTOR
AIR
VENT
BLOWER
BOX
CHIMNEY TOP
COOK TOP
GEAR
MOTOR
COVER
TYPICAL INSTALLATION
3-1/4" X 14"
DUCT CONNECTOR
120 VAC
GROUNDED
OUTLET
COUNTER
TOP
This downdraft blower system
is designed to be used to ex-
haust airborne contaminants
when cooking with a variety of
gas or electric cooktops. It can
be mounted in island, penin-
sula, or conventional wall lo-
cations.
This unit can be easily installed
following these basic steps:
Cut out the countertop
opening.
Mount the unit in the
cabinet.
Install Model 331H, 332H,
335, or 336 External
Blower
Connect the ductwork
and electrical.
Install the cooktop.
2
Downdraft Ventilators
Page 3
1. The interior
downdraft blower
system is designed
for use with 3-1/4" x
10" ductwork (can be
transitioned to 6"
round). Three
different discharge
directions are
available with side-to-
side adjustment for
accurate alignment of
ductwork.
2. For best performance:
Choose the ducting
option which allows
the shortest length of
ductwork and a
minimum number of
RIGHT
DISCHARGE
DOWN DISCHARGE
LEFT
DISCHARGE
PLAN THE DUCTWORK
Interior Blower Installation Exterior Blower Installation
EQUALS 8 FT. OF
STRAIGHT DUCT
6" ROUND
ELBOW
EQUALS 14 FT. OF
STRAIGHT DUCT
3. The system will operate most efficiently when the ductwork
does not exceed 40 feet of equivalent duct. The chart, above,
shows equivalent feet of elbows and transitions. The number
of feet of straight duct plus the equivalent feet of transitions
and/or elbows to be used should equal 40 feet or less.
NOTE: The equivalent feet of various roof and wall caps has
been taken into consideration. Do not include them in this
calculation.
3-1/4" X 10" TO 6" RD.
TRANSITION 3-1/4" X 10"
90O ELBOW
elbows and transitions. Check location of floor joists, wall
studs, electrical wiring or plumbing for possible interfer-
ence.
EQUALS
2 FT. OF
STRAIGHT DUCT
1. The exterior
downdraft blower
system is designed
for use with 3-1/4" x
14" ductwork (can be
transitioned to 8"
round). Three
different discharge
directions are
available with side-
to-side adjustment for
accurate alignment of
ductwork.
2. For best perfor-
mance: Choose the
ducting option which
allows the shortest
length of ductwork
and a minimum
RIGHT
DISCHARGE
DOWN DISCHARGE
LEFT
DISCHARGE
EQUALS 11 FT. OF
STRAIGHT DUCT
8" ROUND ELBOW
EQUALS 19 FT. OF
STRAIGHT DUCT
3. The system will operate most efficiently when the ductwork
does not exceed 40 feet of equivalent duct. The chart, above,
shows equivalent feet of elbows and transitions. The number
of feet of straight duct plus the equivalent feet of transitions
and/or elbows to be used should equal 40 feet or less.
NOTE: The equivalent feet of various roof and wall caps has
been taken into consideration. Do not include them in this
calculation.
3-1/4" X 14" TO 8" RD.
TRANSITION 3-1/4" X 14" 90O
ELBOW
number of elbows and transitions. Check location of floor
joists, wall studs, electrical wiring or plumbing for possible
interference.
EQUALS
5 FT. OF
STRAIGHT
DUCT
Interior Blower Installation Exterior Blower Installation
TAKE MEASUREMENTS (CONTINUED)
SIDE VIEW
OF DOWNDRAFT
SIDE VIEW
OF DOWNDRAFT


Product specificaties

Merk: Broan
Categorie: Afzuigkap
Model: RMDD3604EX

Heb je hulp nodig?

Als je hulp nodig hebt met Broan RMDD3604EX stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Afzuigkap Broan

Handleiding Afzuigkap

Nieuwste handleidingen voor Afzuigkap