Bekijk gratis de handleiding van Bogen RIO1S (8 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 14 mensen en kreeg gemiddeld 4.8 sterren uit 7.5 reviews. Heb je een vraag over Bogen RIO1S of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/8

RIO S1
Relay / Input / Output
Transformer-Balanced Module
Features
• Transformer-isolated, balanced line-level input
• 600-ohm or 0k-ohm jumper-selectable input impedance1
• Transformer-isolated, balanced line-level output
• 8-ohm, 750mW output
• Input and output level controls
• Relay responds to selectable priority level
• External control of priority muting
• N.O. or N.C. relay contacts
• Input can be muted from higher priority modules, with signal fade back
• Output can activate with relay priority level
• Screw terminal strips
• RJ11 connection with line output and dedicated N.O. relay contact
© 2007 Bogen Communications, Inc.
54-2097-01F 0706
Specifications subject to change without notice.

2
Module Installation
1. Turn off all power to the unit.
2. Make all necessary jumper selections.
3. Position module in front of any desired module bay opening, making sure that
the module is right-side up.
4. Slide module onto card guide rails. Make sure that both the top and bottom guides
are engaged.
5. Push the module into the bay until the faceplate contacts the unit’s chassis.
6. Use the two screws included to secure the module to the unit.
WARNING:
Turn off power to unit and make all jumper
selections before installing module in unit.
Note:
This module may include a break-away tab as pictured below. If present, remove this
tab to install module in input module bays.

3
Gain (Input)
Provides control over the level of
input signal.
Level (Output)
Provides control over the level of
output signal.
RJ Connection11
This connector contains the out-
put signal and a set of normally
open relay contacts. It acts similar
to telephone systems’ page ports
and facilitates interfacing to paging
systems with override capabilities
(PCM2000, ZPM3).
Signal Output
Transformer-balanced, low-imped-
ance (8-ohm) line-level output.
Input Signal
Transformer-balanced, line-level
input.
Mute + / Mute -
Provides access to the mute bus
priority system. Allows external
equipment to directly control the
internal mute buses. Prioritized Relay Output
Provides access to the priority
controlled relay contacts. Can be
jumper configured as normally
open (N.O.) or normally closed
(N.C.).
Controls and Connectors
Product specificaties
Merk: | Bogen |
Categorie: | Niet gecategoriseerd |
Model: | RIO1S |
Heb je hulp nodig?
Als je hulp nodig hebt met Bogen RIO1S stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Niet gecategoriseerd Bogen
15 Juni 2025
15 Juni 2025
15 Juni 2025
23 Mei 2025
22 Mei 2025
21 Mei 2025
21 Mei 2025
21 Mei 2025
21 Mei 2025
21 Mei 2025
Handleiding Niet gecategoriseerd
- HammerSmith
- Satechi
- Hartke
- Navitel
- Metronic
- Moomin
- Electrolux
- Storm Audio
- Bliss Outdoors
- Amiko
- Leef
- Ledvance
- CDVI
- Greenworks
- Atosa
Nieuwste handleidingen voor Niet gecategoriseerd
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025