Blomberg DKL 5010 X Handleiding

Blomberg Afzuigkap DKL 5010 X

Lees hieronder de đź“– handleiding in het Nederlandse voor Blomberg DKL 5010 X (24 pagina's) in de categorie Afzuigkap. Deze handleiding was nuttig voor 19 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/24
Cooker Hood
Dunstabzugshaube
Hotte
DKP 2010 X
DKL 5010 X
Instructions Booklet
Bedienungsanleitung
Mode d’emploi
Instructieboekje
GEBRUIKSAANWIJZINGEN............................................ 12
WAARSCHUWING! ....................................................................... 12
AANSLUITING OP HET ELEKTRICITEITSNET ..................................... 12
INHOUD ...................................................................................... 12
INSTALLATIE ................................................................ 13
WERKING .................................................................... 14
ONDERHOUD ............................................................... 15
This appliance has been designed for use as either an (ducting to the EXTRACTION
outside) or RECIRCULATION (filtering) hood.
The measurements contained on the drawings in this booklet refer to two models
of cooker hood. Therefore, it is essential that you refer to the correct drawing
when taking measurements for installation.
WARNINGS!
- The minimum distance between the cooking surface and the metal grease filters on the
underside of the hood must be 650mm.
- This cooker hood must be installed in accordance with the installation instructions
and all requirements must be adhered to.
- If the room where the cooker hood is to be used contains a fuel burning appliance
such as a central heating boiler then its flue must be of the room sealed or balance
flue type.
- If other types of flue or appliances are fitted ensure that there is an adequate supply
of air to the room.
- When the cooker hood is used in conjunction with appliances supplied with energy
other than electricity, the negative pressure in the room must not exceed 0.4 mbar to
prevent fumes being drawn back into the room by the hood.
- The ducting system for this appliance must not be connected to any ventilation system
which is being used for any other purpose.
- The ducting system for this appliance must not be connected to any existing ventilation
system which is being used for any other purpose.
- Do not leave naked flames or carry out flambe cooking under this cooker hood.
CONNECTION TO THE MAINS
WARNING: DOUBLE INSULATED DO NOT EARTH
Before connecting to the mains supply ensure the mains voltage corresponds to the
voltage on the rating plate inside the hood.
This appliance is fitted with a 2 core mains cable and must be permanently connected to
the electricity supply via a double-pole switch having 3mm minimum contact gap on
each pole.
Aplied norms:
EN 60355-1/88 (CEI 61-50/89) CEI EN 61000-3-2/95
EN 60335-2-31 (CEI 61-92/91) CEI EN 61000-3-3/95
CEI EN 55014/94 EN 55104/95
CONTENTS
- 2 No Wall Brackets C
- 1 No Locking Washer D
- 1 No Ducting Flange E
- 1 No 150-120mm Ducting Spigot G
- 1 No Air Deflector H
- 2 No Charcoal Filters (Optional)L
INSTRUCTIONS FOR USE
1


Product specificaties

Merk: Blomberg
Categorie: Afzuigkap
Model: DKL 5010 X
Soort bediening: Knoppen
Kleur van het product: Roestvrijstaal
Gewicht: 13500 g
Breedte: 898 mm
Diepte: 502 mm
Hoogte: 1140 mm
Geluidsniveau: 61 dB
Gewicht verpakking: 17000 g
Soort: Muurmontage
Aantal motors: 1
Maximale afzuigcapaciteit: 390 mÂł/uur
Afzuigmethode: Afvoerend/recirculerend
Aantal lampen: 2 gloeilamp(en)
Hoogte (min): 740 mm
Hoogte (max): 1140 mm
Vermogen lamp: 40 W
Aantal snelheden: 3
Intensieve stand: Nee
Afmetingen verpakking (BxDxH): 965 x 365 x 630 mm

Heb je hulp nodig?

Als je hulp nodig hebt met Blomberg DKL 5010 X stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Afzuigkap Blomberg

Handleiding Afzuigkap

Nieuwste handleidingen voor Afzuigkap