Bertazzoni KMC36NE Handleiding


Lees hieronder de ๐Ÿ“– handleiding in het Nederlandse voor Bertazzoni KMC36NE (68 pagina's) in de categorie Afzuigkap. Deze handleiding was nuttig voor 27 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/68
KMC30X
KMC30BI
KMC30NE
KMC36X
KMC36BI
KMC36NE
KMC48X
KMC48BI
KMC48NE
Installation Instructions
Use and Care Information
Instructions d'installation
Utilisez et d'entretien
2
READ AND SAVE THESE INSTRUCTIONS BEFORE YOU START
INSTALLING THIS RANGEHOOD
WARNING: - TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings. Boilovers cause smoking and
greasy spillovers that may ignite. Heat oils slowly on low or medium setting.
b)๎˜ƒAlways๎˜ƒturn๎˜ƒhood๎˜ƒON๎˜ƒwhen๎˜ƒcooking๎˜ƒat๎˜ƒhigh๎˜ƒheat๎˜ƒor๎˜ƒwhen๎˜ƒ๎™ฌambeing๎˜ƒfood๎˜ƒ(i.e.๎˜ƒCrepes๎˜ƒ
Suzette, Cherries Jubilee, Peppercorn Beef Flambรฉ).
c) Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan
or๎˜ƒ๎™ซlter.๎˜ƒ๎˜ƒ
d) Use proper pan size. Always use cookware appropriate for the size of the surface element.
WARNING: - TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A
RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING*:
a)๎˜ƒSMOTHER๎˜ƒFLAMES๎˜ƒwith๎˜ƒa๎˜ƒclose-๎™ซtting๎˜ƒlid,๎˜ƒcookie๎˜ƒsheet,๎˜ƒor๎˜ƒmetal๎˜ƒtray,๎˜ƒthen๎˜ƒturn๎˜ƒoff๎˜ƒthe๎˜ƒburner.๎˜ƒ๎˜ƒ
BE๎˜ƒCAREFUL๎˜ƒTO๎˜ƒPREVENT๎˜ƒBURNS.๎˜ƒ๎˜ƒIf๎˜ƒthe๎˜ƒ๎™ฌames๎˜ƒdo๎˜ƒnot๎˜ƒgo๎˜ƒout๎˜ƒimmediately๎˜ƒEVACUATE๎˜ƒ
AND CALL THE FIRE DEPARTMENT.
b) NEVER PICK UP A FLAMING PAN - You may be burned.
c) DO NOT USE WATER, including wet dishcloths or towels - a violent steam explosion will
result.
d) Use an extinguisher ONLY if:
1. You know you have a Class ABC extinguisher, and you already know how to operate it.
๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ2.๎˜ƒ The๎˜ƒ๎™ซre๎˜ƒis๎˜ƒsmall๎˜ƒand๎˜ƒcontained๎˜ƒin๎˜ƒthe๎˜ƒarea๎˜ƒwhere๎˜ƒit๎˜ƒstarted.๎˜ƒ๎˜ƒ
๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ3.๎˜ƒ The๎˜ƒ๎™ซre๎˜ƒdepartment๎˜ƒis๎˜ƒbeing๎˜ƒcalled.๎˜ƒ๎˜ƒ
๎˜ƒ๎˜ƒ๎˜ƒ๎˜ƒ4.๎˜ƒ You๎˜ƒcan๎˜ƒ๎™ซght๎˜ƒthe๎˜ƒ๎™ซre๎˜ƒwith๎˜ƒyour๎˜ƒback๎˜ƒto๎˜ƒan๎˜ƒexit.
* Based on "Kitchen Firesafety Tips" published by NFPA
WARNING - TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, do not use this
fan with any solid-state speed control device.
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO
PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you have any
questions, contact the manufacturer.
2. Before servicing or cleaning unit, switch power off at service panel and lock the
service disconnecting means to prevent power from being switched on acciden-
tally. When the service disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
CAUTION: For General Ventilating Use Only. Do Not Use To Exhaust Hazardous or
Explosive Materials and Vapors.
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO
PERSONS, OBSERVE THE FOLLOWING:
1. Installation๎˜ƒWork๎˜ƒAnd๎˜ƒElectrical๎˜ƒWiring๎˜ƒMust๎˜ƒBe๎˜ƒDone๎˜ƒBy๎˜ƒQuali๎™ซed๎˜ƒPerson(s)๎˜ƒIn๎˜ƒAccor-
dance With All Applicable Codes And Standards, Including Fire-Rated Construction.
2. Suf๎™ซcient๎˜ƒ air๎˜ƒ is๎˜ƒneeded๎˜ƒfor๎˜ƒ proper๎˜ƒ combustion๎˜ƒand๎˜ƒ exhausting๎˜ƒof๎˜ƒ gases๎˜ƒthrough๎˜ƒ
the๎˜ƒ๎™ฌue๎˜ƒ (chimney)๎˜ƒ of๎˜ƒ fuel๎˜ƒburning๎˜ƒequipment๎˜ƒ to๎˜ƒprevent๎˜ƒbackdrafting.๎˜ƒFollow๎˜ƒthe๎˜ƒ
heating equipment manufacturer's guideline and safety standards such as those
published๎˜ƒ by๎˜ƒ the๎˜ƒ National๎˜ƒ Fire๎˜ƒ Protection๎˜ƒ Association๎˜ƒ (NFPA),๎˜ƒ and๎˜ƒ the๎˜ƒ American๎˜ƒ
Society๎˜ƒfor๎˜ƒHeating,๎˜ƒRefrigeration๎˜ƒand๎˜ƒAir๎˜ƒConditioning๎˜ƒEngineers๎˜ƒ(ASHRAE),๎˜ƒand๎˜ƒ
the local code authorities.
3
ALL WALL AND FLOOR OPENINGS WHERE THE RANGEHOOD
IS INSTALLED MUST BE SEALED.
This rangehood requires at least 24" of clearance between the bottom of the rangehood and the
cooking surface or countertop. This hood has been approved by UL at this distance from the cooktop.
This minimum clearance may be higher depending on local building codes. For gas cooktops and
combination ranges, a minimum of 30" is recommended and may be required.
Overhead cabinets on both sides of this unit must be a minimum of 18" above the cooking surface
or countertop. Consult the cooktop or range installation instructions given by the manufacturer before
making any cutouts.
MOBILE HOME INSTALLATION The installation of this rangehood must conform to the Manufactured
Home Construction and Safety Standards, Title 24 CFR, Part 3280 (formerly Federal Standard for
Mobile Home Construction and Safety, Title 24, HUD, Part 280). See Electrical Requirements.
VENTING REQUIREMENTS
Determine which venting method is best for your application. Ductwork can extend either through the
wall or the roof.
The length of the ductwork and the number of elbows should be kept to a minimum to provide ef๎™ชcient
performance. The size of the ductwork should be uniform. Do not install two elbows together. Use
duct tape to seal all joints in the ductwork system. Use caulking to seal exterior wall or ๎™ซoor opening
around the cap.
Flexible ductwork is not recommended. Flexible ductwork creates back pressure and air turbulence
that greatly reduces performance.
Make sure there is proper clearance within the wall or ๎™ซoor for exhaust duct before making cutouts.
Do not cut a joist or stud unless absolutely necessary. If a joist or stud must be cut, then a supporting
frame must be constructed.
WARNING - To Reduce The Risk Of Fire, Use Only Metal Ductwork.
CAUTION๎˜ƒ-๎˜ƒTo๎˜ƒreduce๎˜ƒrisk๎˜ƒof๎˜ƒ๎™ซre๎˜ƒand๎˜ƒto๎˜ƒproperly๎˜ƒexhaust๎˜ƒair,๎˜ƒbe๎˜ƒsure๎˜ƒto๎˜ƒduct๎˜ƒair๎˜ƒoutside๎˜ƒโ€“๎˜ƒDo๎˜ƒ
not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces, or garages.
3. When cutting or drilling into wall or ceiling, do not damage electrical wiring and
other hidden utilities.
4. Ducted fans must always be vented to the outdoors.
โ€ข Venting system MUST terminate outside the home.
โ€ข DO NOT terminate the ductwork in an attic or other enclosed space.
โ€ข DO NOT use 4" laundry-type wall caps.
โ€ข Flexible-type ductwork is not recommended.
โ€ข DO NOT obstruct the ๎™ซow of combustion and ventilation air.
โ€ข Failure to follow venting requirements may result in a ๎™ชre.
WARNING
Cold Weather installations
An additional back draft damper should be installed to minimize backward cold air ๎™ซow and a
nonmetallic thermal break should be installed to minimize conduction of outside temperatures as
part of the vent system. The damper should be on the cold air side of the thermal break. The break
should be as close as possible to where the vent system enters the heated portion of the house.


Product specificaties

Merk: Bertazzoni
Categorie: Afzuigkap
Model: KMC36NE

Heb je hulp nodig?

Als je hulp nodig hebt met Bertazzoni KMC36NE stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Afzuigkap Bertazzoni

Handleiding Afzuigkap

Nieuwste handleidingen voor Afzuigkap