Arris Touchstone BPB044S Handleiding

Arris Accu Touchstone BPB044S

Lees hieronder de 📖 handleiding in het Nederlandse voor Arris Touchstone BPB044S (12 pagina's) in de categorie Accu. Deze handleiding was nuttig voor 34 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/12
STANDARD Revision 2 © 2016 ARRIS Enterprises LLC. All Rights Reserved. 1
Setting the Standard for Battery Backup Solutions
ARRIS pioneered using Lithium Ion) battery technology in DOCSIS® compliant Touchstone® Embedded - -Ion (Li
Multimedia Terminal Adapters (E-MTAs) in 2003. ARRIS battery back-up solutions optimize E-MTA performance for
lifeline telephony, reduce risk through multiple protection mechanisms, and maximize battery life with proprietary low
power designs. ARRIS superior battery technology ensures that all Touchstone battery products provide -backed E- MTA
unsurpassed quality, safety, and value within the industry.
Lithium-Ion Technology Leadership
ARRIS battery packs come in 2, 4, 6, and 8-cell configurations. ARRIS maintains a comprehensive cell and pack
qualification process, which includes safety qualification testing, electrical performance analysis, and rigorous
manufacturing standards. With ARRIS batteries, Cable Operators can count on hours of dependable voice service during
a local power outage.
Environmentally Friendly ARRIS "Green"
ARRIS is pleased to provide products that meet the Restriction of Hazardous Substances (RoHS) directive. Beyond the
present directive to remove lead and other heavy metals, ARRIS has increased our focus by removing other
environmentally impacting materials from the packaging, cables, and other accessories. Please contact your sales
representative for more information.
In many areas, consumers are not allowed to dispose of lithium-based batteries as household waste. To minimize the
inconvenience of recycling used batteries, ARRIS has partnered with Call2Recycle for proper disposal. For information
about the battery recycling and disposal program, visit the Call2Recycle (http://www.call2recycle.org/) website.
Touchstone®
Quick Reference
Touchston
STANDARD Revision 2 © 2016 ARRIS Enterprises LLC. All Rights Reserved. 2
Minimum 8 up Time by Model- -Hour Hold
An 8 hour hold- -up time means the device can support voice service for at least 8 hours. The actual talk time available is
5 hours. The following factors can affect hold- up time:
Battery age most batteries hav e a service life (when the battery can provide the rated hold-up time) of at least 5
years. ARRIS warrants batteries for 1 year.
A high number of charge and discharge cycles whether caused by frequent outages, or frequently disconnecting
power (by unplugging the unit or putting it on a switched outlet) can reduce battery service life.
Ambient temperature—rated capacity and service life assumes room temperature (72°F or 22°C). Lower
temperatures may increase service life while reducing capacity, and higher temperatures may increase capacity
while decreasing service life.
The following table shows the minimum battery size required to provide an 8- -hour hold up time for each listed model.
The following conditions apply:
The battery is new.
The battery is fully charged.
The battery remains at room temperature: 72°F (22°C) at all times.
Model -Minimum Battery for 8 hour Hold up Time-
Model # - Part # (single) Part # (10 pack)
TM602G BPB022S 790513 718003
TM604G BPB044S 790512 718005
TM608G BPB044S 790512 718005
WTM652G BPB026S 794068 789699
TM722G BPB044S 790512 718005
TM802G BPB026S 794068 789699
TM804G BPB026S 794068 789699
TM822G BPB026S 794068 789699
TG852G BPB026S 794068 789699
TG862G BPB026S 794068 789699
TM1602G, TM3202G BPB044S 790512 718005
TG1662G, TG1672G,
TG1682G, TG2472G
BPB044S 790512 718005
When installing or replacing a battery in a Touchstone device, it typically takes up to 72 hours to calibrate and charge.
The device repeats the calibration cycle:
After the battery has been totally depleted.
Touchston
STANDARD Revision 2 © 2016 ARRIS Enterprises LLC. All Rights Reserved . 3
Approximately every 6 months, as part of routine battery maintenance.
On loss of AC power, all units shut down data services (WiFi, Ethernet, and USB as applicable) either immediately or
after several minutes depending on model. If continued data service during an outage is required, use a UPS to maintain
AC power.
While operating on battery power, the Touchstone® E MTA supports analog telephones plugged into a telephone jack. -
However, cordless telephones or other phones that require AC power will not work unless powered by their own backup
power source.
The following table provides detailed information about battery support and hold up times per model for each -
supported battery type.
Model # BPB022S BPB026S BPB044S BPB088S BPB044H BPD066H BPC088S BPD088H
Part # (single) 790513 794068 790512 - - 790514 - 802251
Part # (10- 718003 789699 718005 722841 785170 721192 722842 785171pack)
Capacity (Ah) 2.2 2.6 4.4 4.4 6.6 8.8 8.8 8.8
TM502
Idle 5 5 10 10 - - - -
1 line off-hook 3 3 6 6 - - - -
2 lines off-hook 2 2 4 4 - - - -
TM504
Idle 4 4 8 - - 16 - -
1 line off-hook 3 3 6 - - 12 - -
2 lines off-hook 2 2 4 - - 8 - -
3 lines off-hook 1.75 1.75 3.5 - - 7.5 - -
4 lines off-hook 1.5 1.5 3 - - 7 - -
WTM552
Idle 5 5 10 - - - - -
1- -line off hook 3 3 6 - - - - -
2- -lines off hook 2 2 4 - - - - -
TM602v2
Idle 8 8 12 12 - 24 - -
1- -line off hook 5 5 8 8 - 16 - -
2- -lines off hook 4 4 6 6 - 13 - -
DTM602
Idle 4 5 8 8 - - - -
1- -line off hook 2.5 3 5 5 - - - -
2- -lines off hook 1.5 2 4 4 - - - -
TM604
Idle 6 7 12 12 - 24 - -
1- -line off hook 4 5 8 8 - 16 - -