APSystems DS3-L Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor APSystems DS3-L (22 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 41 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/22
Please scan this QR code to have
access to our APPs and Products
informaon
APsystems DS3 series
DS3-L and DS3 Microinverters
EMEA region
Installaon Manual
ALTENERGY POWER SYSTEM Inc.
emea.APsystems.com
APsystems
Cypresbaan 7, 2908 LT, Capelle aan den Ijssel
The Netherlands
Tel: +31- - info.emea@APsystems.com10 2582670 EMAIL:
Rue des Monts d’Or, ZAC de Folliouses Sud-Les Echets 01700 Miribel,
France
TEL: +33- - - -40 EMAIL:info.emea@APsystems.com481 65 60
© All Rights Reserved
APsystems DS3 series Installaon/User Manual
1
Table of Contents
1.Important Safety Instrucons ...................................................................................................... 2
1.1 Safety Instrucons ...................................................................................................................................... 2
1.2 Radio Interference Statement .................................................................................................................... 3
1.3 Symbols replace words on the equipment, on a display, or in manuals ................................................... 4
2.APsystems Microinverter System Introducon............................................................................ 5
2.1 Key elements of an APsystems system ....................................................................................................... 5
2.2 The advantages of an APsystems system ................................................................................................... 6
3.APsystems Microinverter DS3 series Introducon ....................................................................... 7
3.1 Characteriscs of the DS3 microinverter .................................................................................................... 7
3.2 Features of the DS3 microinverter.............................................................................................................. 7
4.APsystems Microinverter System Installaon.............................................................................. 8
4.1 Addional accessories supplied by APsystems .......................................................................................... 8
4.2 Other required accessories not supplied by APsystems ............................................................................ 8
4.3 Installaon Procedures ............................................................................................................................... 9
4.3.1 Step 1 - Verify that grid voltage is matching with microinverter rang ......................................... 9
4.3.2 Step 2 Y3 AC Bus Cable distribuon– ............................................................................................. 9
4.3.3 Step 3 - Attach the APsystems Microinverters to the Racking ........................................................ 9
4.3.4 Step 4 - Ground the system ............................................................................................................ 10
4.3.5 Step 5 - Connect the APsystems microinverter to AC bus cable ................................................... 10
4.3.6 Step 6 - Install a Bus Cable End Cap at the end of AC bus cable ....................................................11
4.3.7 Step 7 - Connect APsystems Microinverters to the PV Modules .................................................. 12
4.3.8 Step 8 - Complete the APsystems installaon map ...................................................................... 13
4.3.9 Step 9 - Warning Noce ................................................................................................................. 13
5. Microinverter system operang instrucons ............................................................................ 14
6.Troubleshoong ......................................................................................................................... 15
6.1 Status Indicaons and Error Reporng .................................................................................................... 15
6.1.1 Start up LED .................................................................................................................................... 15
6.1.2 Operaon LED ................................................................................................................................ 15
6.1.3 GFDI Error ....................................................................................................................................... 15
6.2 ECU_APP .................................................................................................................................................... 15
6.3 Installer EMA (web portal or EMA Manager APP) ................................................................................... 15
6.4 Trouble Shoong Guide ............................................................................................................................ 15
6.5 APsystems Technical Support ................................................................................................................... 16
6.6 Maintenance ............................................................................................................................................. 16
7.Replace a microinverter............................................................................................................. 17
8.Technical Data ............................................................................................................................ 18
8.1 DS3 series Microinverter Datasheet ......................................................................................................... 19
9. DS3 series - Wiring Diagram ..................................................................................................... 20
9.1 Sample Wiring Diagram - Single Phase ..................................................................................................... 20
10 APsystems Microinverter & Energy Communication Unit Installaon Map ............................. 21
APsystems DS3 series Installaon Manual
2
1.Important Safety Instrucons
This manual contains important instrucons to follow during installaon and maintenance of the APsystems
Photovoltaic Grid-connected Microinverter. To reduce the risk of electrical shock and ensure a safe installaon and
operaon of the APsystems Microinverter, the following symbols appear throughout this document to indicate
dangerous condions and important safety instrucons.
Specicaons are subject to change without noce. Please ensure you are using the most recent update found at
hps://emea.apsystems.com/resources/library/
This indicates informaon that is important for opmized microinverter operaon. Follow these instrucons
closely.
1.1 Safety Instrucons
 Only qualified professionals should install and/or replace APsystems Microinverters.
 Perform all electrical installaons in accordance with local electrical codes.
 Before installing or using the APsystems Microinverter, please read all instrucons and cauonary markings
in the technical documents and on the APsystems Microinverter system and the solar array.
 Do NOT disconnect the PV module from the APsystems Microinverter without rst disconnecng the AC
power.
 Be aware that the body of the APsystems Microinverter is the heat sink and can reach a temperature of 80°C.
To reduce risk of burns, do not touch the body of the Microinverter.
 Do NOT attempt to repair the APsystems Microinverter. If the micro is suspected to be faulty, please contact
your local APsystems Technical Support to start troubleshoong and obtain a RMA (Return Merchandise
Authorizaon) number to start the replacement process if needed. Damaging or opening the APsystems
Microinverter will void the warranty.
 Cauon!
When connecng a microinverter, it is recommended to rst connect the AC Bus cable to the ground then
connect the AC connector to ensure proper earthing of the micro-inverter, then do the DC connecons. When
disconnecng a microinverter disconnect the AC by opening the branch circuit breaker rst but maintain the
protective earthing conductor in the branch circuit breaker connected to the microinverter, then disconnect
the DC inputs.
 Please install AC breakers on the AC side of the inverter.


Product specificaties

Merk: APSystems
Categorie: Niet gecategoriseerd
Model: DS3-L

Heb je hulp nodig?

Als je hulp nodig hebt met APSystems DS3-L stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd APSystems

APSystems

APSystems DS3 Handleiding

27 Februari 2024
APSystems

APSystems DS3-L Handleiding

27 Februari 2024

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd