AMX HydraPort HPX-P200 Handleiding
AMX
Niet gecategoriseerd
HydraPort HPX-P200
Lees hieronder de 📖 handleiding in het Nederlandse voor AMX HydraPort HPX-P200 (2 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 2 personen en werd door 1.5 gebruikers gemiddeld met 4.7 sterren beoordeeld
Pagina 1/2

QUICK START GUIDE
HPX-P200/P250-PC-xx HydraPort
®
Power Outlet Modules
Overview
HPX-P200/P250-PC-xx HydraPort AC Power Modules are used exclusively in the AMX
HydraPort (HPX-600/900/1200) and HydraPort Touch (HPX-MSP-7/10) chassis which
are designed to be mounted in a horizontal surface such as a conference room table or
lectern. Refer to the installation guide for the HydraPort 600/900/1200 and HydraPort
Touch (HPX-MSP-7/10) units for further instructions.
There are seven models available to accommodate various regional power outlet types
(FIG. 1):
Product Specif ications
FIG. 1 HPX-P200/250-PC XX POWER MODULES
HPX-P250-PC-UK (FG561-11)
Power Outlet (UK) Module
HPX-P200-PC-EU (FG561-21)
Power Outlet (EU) Module
HPX-P200-PC-AU (FG561-31)
Power Outlet (Australia) Module
HPX-P250-PC-IN (FG561-41)
Power Outlet (India, South Africa) Module
HPX-P200-PC-BR (FG561-71)
Power Outlet (Brazil) Module
HPX-P200-PC-EU2 (FG561-61)
Power Outlet (France, Belgium) Module
HPX-P200-PC-ITY (FG561-81)
Power Outlet (Italy, Chile) Module
HPX-P250-PC-UK
Provides power connectivity to the HydraPort chassis for Type G plug types used in the UK.
Dimensions (HWD): 62.5mm x 66mm x 75mm (2.5" x 2.6" x 2.95")
Module Spaces 2.5 HydraPort Units
Weight: 0.5 Kg (1 lbs)
Enclosure Black Polycarbonate UL94v0 material
Rear Connections IEC C320 C13 Socket
HPX-P200-PC-EU
Provides power connectivity to the HydraPort chassis for Type F plug types used in the EU.
Dimensions (HWD): 50mm x 66mm x 85mm (2.0" x 2.6" x 3.3")
Module Spaces 2 HydraPort Units
Weight: 0.5 Kg (1 lbs)
Enclosure Black Polycarbonate UL94v0 material
Rear Connections IEC C320 C13 Socket
HPX-P250-PC-AU
Provides power connectivity to the HydraPort chassis for Type I plug types used in Australia.
Dimensions (HWD): 50mm x 66mm x 70mm (2.0" x 2.6" x 2.8")
Module Spaces 2 HydraPort Units
Weight: 0.5 Kg (1 lbs)
Enclosure Black Polycarbonate UL94v0 material
Rear Connections IEC C320 C13 Socket
HPX-P250-PC-IN
Provides power connectivity to the HydraPort chassis for type M plug types used in India
and South Africa.
Dimensions (HWD): 62.5mm x 66mm x 76mm (2.5" x 2.6" x 3.0")
Module Spaces 2.5 HydraPort Units
Weight: 0.5 Kg (1 lbs)
Enclosure Black Polycarbonate UL94v0 material
Rear Connections IEC C320 C13 Socket
HPX-P200-PC-EU2
Provides power connectivity to the HydraPort chassis for Type E plug types used in
France and Belgium.
Dimensions (HWD): 50mm x 66mm x 85mm (2.0" x 2.6" x 3.3")
Module Spaces 2 HydraPort Units
Weight: 0.5 Kg (1 lbs)
Enclosure Black Polycarbonate UL94v0 material
Rear Connections IEC C320 C13 Socket
HPX-P200-PC-BR
Provides power connectivity to the HydraPort chassis for Type N plug types used in Brazil.
Dimensions (HWD): 50mm x 66mm x 85mm (2.0" x 2.6" x 3.3")
Module Spaces 2 HydraPort Units
Weight: 0.5 Kg (1 lbs)
Enclosure Black Polycarbonate UL94v0 material
Rear Connections IEC C320 C13 Socket
HPX-P200-PC-ITY
Provides power connectivity to the HydraPort chassis for Type L plug types used in Italy
and Chile.
Dimensions (HWD): 50mm x 66mm x 87mm (2.0" x 2.6" x 3.4")
Module Spaces 2 HydraPort Units
Weight: 0.5 Kg (1 lbs)
Enclosure Black Polycarbonate UL94v0 material
Rear Connections IEC C320 C13 Socket

© 2016 Harman. All rights reserved. HydraPort, AMX, AV FOR AN IT WORLD, HARMAN, and their respective logos are registered trademarks of
HARMAN. Oracle, Java and any other company or brand name referenced may be trademarks/registered trademarks of their respective
companies.
AMX does not assume responsibility for errors or omissions. AMX also reserves the right to alter specifications without prior notice at any time.
The AMX Warranty and Return Policy and related documents can be viewed/downloaded at www.amx.com.
3000 RESEARCH DRIVE, RICHARDSON, TX 75082 AMX.com | 800.222.0193 | 469.624.8000 | +1.469.624.7400 | fax 469.624.7153
AMX (UK) LTD, AMX by HARMAN - Auster Road, Clifton Moor, York, YO30 4GD United Kingdom • +44 1904-343-100 • www.amx.com/eu/
93-0561-02 REV: G
Last Revised: 7/19/2016
Installation
Caution: Only a professional, AMX-qualified installer should perform this installation or
servicing. This product may not be installed or serviced by the end-user.
- Ensure that the socket/outlet meets all regulatory requirements for your region
and complies with all applicable local safety and electrical codes and standards. It
is the responsibility of the installer to ensure compliance to any applicable codes.
- AMX recommends using sleeved plugs and keeping all earthing/grounding pins
intact in order to reduce the risk of electric shock to the user.
- Use caution with plugs that do not allow earthing/grounding. Disconnect all AC
Power Cords from the AC Mains Power Branch Circuit until installation is complete.
Note: Refer to the Installation guide for instructions on installation and removal of the
HPX-600/900/1200.
Tools Required
• #2 Phillips Screwdriver
Remove the HPX-600/900/1200 (if required)
1. Remove the HPX-600/900/1200 from the mounting surface if it has previously
been installed in a mounting surface.
Install the HPX-P200/250-PC-xx Power Module
2. Remove one of the plastic end caps from the HPX-600/900/1200:
a. Remove the silver #6 screw retaining the pawl and door
b. Remove the six #6 black sheet metal screws retaining the plastic end cap to
the metal frame
c. Slip the plastic end cap off the metal frame
3. Remove existing modules or blanks to install the AC Power Module.
4. Insert the AC Power Module into the metal frame by sliding it into the slots
provided in the metal frame.
Note the orientation of the interlocking tabs. The interlocking tabs on each
module should all be facing towards the same end of the chassis (see FIG. 2 on
reverse).
5. Replace the plastic end cap by replacing the 6 #6 sheet metal screws and the #6
screw retaining the pawl and door.
Note: Do not over-tighten the pivot pawl screw (do not use a high-powered drill on
this screw).
6. Install a suitable power cord compliant with local safety standards.
a. Insert the power cord's C14 connector into the IEC C320 C13 Socket
provided on the rear of the power module.
b. Secure the power cord to the chassis using a suitable tie-wrap and one or
more of the plastic clips provided with the HPX-600/900/1200.
Replace the HPX-600/900/1200
7. Reinstall the HPX-600/900/1200 by reversing Step 1.
Note: Refer to the Installation guide for the HPX-600/900/1200 as required.
Plug the HPX-P200/250-PC-xx into the Branch Circuit
8. Connect an appropriate power cord in to the power module.
9. Plug the power outlet plug into the AC Mains Power Branch Circuit.
FIG. 2 INSTALLING THE HPX-P200/P250-PC-XX MODULE
Interlocking tab
Cables
HPX Base Assembly
Mounting Surface
End Cap
Product specificaties
Merk: | AMX |
Categorie: | Niet gecategoriseerd |
Model: | HydraPort HPX-P200 |
Heb je hulp nodig?
Als je hulp nodig hebt met AMX HydraPort HPX-P200 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Niet gecategoriseerd AMX

9 Juni 2025

9 Juni 2025

9 Juni 2025

9 Juni 2025

9 Juni 2025

9 Juni 2025

9 Juni 2025

9 Juni 2025

24 Mei 2025

23 Mei 2025
Handleiding Niet gecategoriseerd
- Niet gecategoriseerd Yamaha
- Niet gecategoriseerd Pluto
- Niet gecategoriseerd Mackie
- Niet gecategoriseerd Amplicom
- Niet gecategoriseerd Blafili
- Niet gecategoriseerd ViewZ
- Niet gecategoriseerd Plantronics
- Niet gecategoriseerd PreSonus
- Niet gecategoriseerd ETiger
- Niet gecategoriseerd KONFTEL
- Niet gecategoriseerd Rainbow
- Niet gecategoriseerd Technisat
- Niet gecategoriseerd GoPro
- Niet gecategoriseerd Saint Algue
- Niet gecategoriseerd VisionTek
Nieuwste handleidingen voor Niet gecategoriseerd

9 Juni 2025

9 Juni 2025

9 Juni 2025

9 Juni 2025

9 Juni 2025

9 Juni 2025

9 Juni 2025

9 Juni 2025

9 Juni 2025

9 Juni 2025