Amprobe AT-5005 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Amprobe AT-5005 (4 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 100 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/4
www.Amprobe.comAmprobeÂŽ Test Tools
Data Sheet
No hassle
warranty
No waiting.
No shipping
charges.
Our commitment to
high-quality products
and customer service
is demonstrated by
our industry exclusive
“No Hassle” warranty.
In the unlikely event
that an Amprobe Test
Tool requires warranty
service, any of our
local dealers are
authorized to replace
it, on the spot.
(note: $500 MSLP limit)
AT-5005
Professional
Underground Cable /
Pipe Locator System
Buried Utilities represent a major challenge to electricians
who need to trace and trouble shoot such systems. They also
represent a hazard to excavation crews. Improperly performed
digging can cause cable or pipe damage resulting in personal
injury, costly repairs and penalties. This product is faster and
more accurate than what’s available on the market today.
The AT-5005 features A-Frame attachment to pinpoint cable
ground faults in non-destructive way. The optional Pipe
Transmitter allows tracing and locating of non-metallic pipes.
Using superior design and powerful software, the AT-5005
offers several new performance features, establishing them
as the new standard for locating and pinpointing faults in the
underground systems. Distance sensitive Left / Right indication
guides the user to the exact location of the buried utilities
which saves time and effort not available on standard locators.
The Signal Select and Distortion Alert provide superior
accuracy by visually indicating a clean signal of the traced line,
versus “ghost” and ‘return’ path of false signals coming from
the neighboring lines, and keeping the user on the target line.
The core of the AT-5005 Utility Locating Systems is the
ergonomically designed handheld receiver. Designed for
comfort, the lightweight receiver is balanced for all day use.
The receiver’s bright color display is complete with intuitive,
easily read graphics that can be viewed in all lighting
conditions.
600V
www.Amprobe.comAmprobeÂŽ Test Tools
Data Sheet
Locates underground energized and de-energized wires, cables and
pipes, eliminates exploratory digging in parking lots or under floors for
buried pipes and wires
New technology makes tracing much faster, accurate and unambiguous
when compared to standard locators:
– Signal Select and Distortion Alert icon indicates clean signal of the
traced line, versus “ghost” and ‘return’ path signals coming from
the neighboring lines
– Forward-looking Guidance Coil alerts for bends and “T”
– Distance Sensitive Left / Right Guidance guides the user to the
exact location of the buried utilities and eliminates “blind” searches
for the line
Three testing modes for best accuracy:
– Passive Power Mode (50, 60, 100 and 120 Hz) – tracing
energized lines conducting current
– Passive Radio Mode (RF) – using surrounding radio waves to trace
underground object
– Active Mode - T-5000 signal generator with broad frequency
selection between 491 Hz and 166 kHz with induction mode or
directly connected to the cable with test leads or optional clamp
Active Mode Depth measurement up to 20’ (6m)
Bright Color Âź VGA receiver graphical display and audible signal
indicators provide clear reading to the user
Strong testing signal generated by 10 Watt variable output transmitter
for dependable depth and distance locating
Powerful Digital Signal Processing in both receiver and transmitter
provides outstanding performance in tracing when compared to analog
devices
Automatic or manual gain mode allows respectively quick and easy
tracing of the line or precise pinpointing of the fault
Receiver BluetoothÂŽ wireless communication for downloading relevant
images and archiving of meaningful digital information (previous survey
results)
Ground Fault Locating with A-Frame adapter for power and telecom
cables (optional for AT-5000)
Precise pinpointing of buried services and exceptionally
fast sound and meter response
Rugged durable construction, weatherproof
and drop resistant to 3’
Includes receiver (R-5000), transmitter (T-5000),
connection cable, ground stake, ground cable,
carrying case and A-Frame
www.Amprobe.comAmprobeÂŽ Test Tools
Data Sheet
AT-5005 Professional Underground Cable / Pipe Locator System
Specications
Depth Measurement 20 ft
Passive Tracing Frequencies 50, 60, 100 and 120 Hz
Transmitter frequency Adjustable from 491 to 166 kHz
A-Frame Ground Fault Locating Optional
R-5000 Active Frequencies (Hz) 491, 982, 8.44k, 9.82k, 35k, 82k, 83k (North America)
491, 512, 577, 640, 982, 8k, 8.44k, 9.82k, 35k, 65.5k, 82k, 83k
R-5000 Passive Frequencies (Hz) 50, 60, 100, 120, RF (14k-21k)
Extended and special frequency sets available
R-5000 Depth Display Accuracy 0-10ft: ±(5%+2”) under ideal field conditions
10-20ft: ¹10% under ideal eld conditions
R-5000 Depth Range Maximum 20ft (600 cm)
R-5000 Gain Adjustment Automatic & manual with pushbutton centering
R-5000 Controls Four-way navigation key and soft keys
R-5000 Display Indicators Frequency Audio volume, battery condition, Guidance Compass™, Distortion
Alert™, Signal Select™, signal strength, Distance Sensitive Left/ Right
Guidance™, menu softkey, frequency softkey
R-5000 Line ID Signal Select, Guidance Compass, Distortion Alert
R-5000 Display Âź VGA Bright Color
R-5000 Antenna Distance Sensitive Left/Right Guidance
R-5000 Data Acquisition Internal data logging memory
R-5000 Operating Temperature -4°F to +122°F (-20°C to +50°C)
R-5000 Battery Type Li-ion rechargeable
9 AA Alkaline
R-5000 Battery Life 30 hours continuous
R-5000 Battery Check Continuous display
R-5000 Dimensions 8 ¼” W x 13 ¼” H x 29” L (21.0cm x 33.7 cm x 74.3cm)
R-5000 Weight 4.9 lb (2.2 kg)
R R-5000 egulatory Compliance FCC, CE
R-5000 Environmental IP54
T-5000 Output Frequencies (Hz) 491, 982, 8.44k, 9.82k, 35k, 82k, 83k (North America)
491, 577, 640, 982, 8.192k, 8.44k, 9.82k, 35k, 82k, 83k
Extended and special frequency sets available
T-5000 Output Power Variable to 10W
T-5000 Simultaneous Output Up to three active frequencies
T-5000 Controls Frequency select, measurement units (mA, Volts, Ohms, Watts), output power,
Signal Select™, menu, 4-way navigation, select, SFL, On/Off
T-5000 Display Indicators Battery status, audio volume, output mode, frequency setting, frequency out
put, % output in SFL or induction mode, output graph, loop resistance graph
T-5000 Display 1/8 VGA monochrome
T-5000 Battery Type NiMH rechargeable or six (6) D alkaline
T-5000 Battery Life 6 – 12 hours continuous use, depending on power level and line conditions
T-5000 Operation Temperature -4ÂşF to +122Âş F (-20ÂşC to +50Âş C)
T-5000 Dimensions 11” W x 6 ¾” H x 9” L (27.9 cm x 17.1 cm x 22.9 cm)
T-5000 Weight 8.24 lbs. (3.7 kg)
T-5000 Regulatory Compliance FCC, CE
T-5000 Environmental IP54


Product specificaties

Merk: Amprobe
Categorie: Niet gecategoriseerd
Model: AT-5005

Heb je hulp nodig?

Als je hulp nodig hebt met Amprobe AT-5005 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Amprobe

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd