Amprobe ACD-15 TRMS-PRO Handleiding

Amprobe Niet gecategoriseerd ACD-15 TRMS-PRO

Lees hieronder de šŸ“– handleiding in het Nederlandse voor Amprobe ACD-15 TRMS-PRO (4 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 96 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/4
www.Amprobe.comAmprobeĀ® Test Tools
Data Sheet
No hassle
warranty
No waiting.
No shipping
charges.
Our commitment to
high-quality products
and customer service
is demonstrated by
our industry exclusive
ā€œNo Hassleā€ warranty.
In the unlikely event
that an Amprobe Test
Tool requires warranty
service, any of our
local dealers are
authorized to replace
it, on the spot.
(note: $500 MSLP limit)
ACD-15 TRMS-PRO
2000A Clamp-on Multimeter
Wide range of measuring features built into one, professional
meter. The TRMS version with backlight display, improves
performance and reliability.
True RMS
Backlight
Measurements: AC/DC Voltage
up to 600V, AC Current up to
2000A Resistance, Frequency
and Capacitance
Non-contact Voltage Level
Detection
Audible continuity
Auto-check feature
automatically selects DCV,
ACV or Resistance ( )W
Auto power off
Low battery indication
Data hold
Large, easy to read LCD display
Accommodates conductors up to
45mm (1.77ā€) in diameter
Carrying case, test leads, batteries
(installed) and manual included
Voltage overload protection for all
functions up to 600V AC/DC
600V
AmprobeĀ® Test Tools www.Amprobe.com
Data Sheet
ACD-15 TRMS-PRO 2000A Digital Clamp-on Multimeters
DC Voltage
6.000V 0.5% + 3d
60.00V 1.0% + 5d
600.0V 2.0% + 5d
NMRR : >30dB @ 50/60Hz
>100dB @ DC, 50/60Hz, Rs=1k CMRR : W
Hi-Z DCV Input Impedance: 5M , 90pF nominal W
AutoCheckā„¢ Lo-Z DCV input impedance: Initially 1.6k , 90pF nominal; Impedance increases signiļ¬cantly as display voltage W
increases from 50V (typical). Typical impedances vs display voltages for reference are:
15kW @ 100V; 100k @ 300V; 210k @ 600VW W
AutoCheckā„¢ DCV Threshold: > +1.5VDC or < -1.0VDC nominal
AC Voltage
50Hz / 60Hz 6.000V, 60.00V 1.5% + 5d
600.0V 2.0% + 5d
6.000V, 60.00V 2.0% + 5d 50Hz ~ 500Hz
600.0V 2.5% + 5d
CMRR: >60dB @ DC to 60Hz, Rs=1kW
Hi-Z ACV Input Impedance: 5MW, 90pF nominal
AutoCheckā„¢ Lo-Z ACV input impedance: Initially 1.6k , 90pF nominal; Impedance increases signiļ¬cantly as display voltage W
increases from 50V (typical). Typical impedances vs display voltages for reference are:
5kW W @ 100V; 100k @ 300V; 210k @ 600VW
AutoCheckā„¢ ACV Threshold: > 2VAC (50/60Hz) nominal. True RMS model ACD-15 TRMS-PRO Crest < 1.6 : 1 at full scale
& < 3.3 : 1 at half scale
Resistance
6.000kW 2) 1.2% + 6d 1) 3)
60.00kW W, 600.0k 1.0% + 4d
6.000MW 2.0% + 4d
Open Circuit Voltage: 0.4VDC typical 1) Cool down interval 2 minutes after over 50V measurements in Auto-V position W
2) Beeper on while reading < 0.025k W
3) Add 40d to speciļ¬ed accuracy while reading is
600W Wī˜ƒ with Continuity Beeper 600.0 2.0%+8d 1)
Continuity Beeper Response: < 100Āµs
Open Circuit Voltage: 0.4VDC typical
Audible Threshold: between 10 and 300 1) Add 40d to speciļ¬ed accuracy while reading is below W W
20% of range
Frequency
Range Voltage Range Sensitivity (Sine RMS)
10Hz ~ 30kHz 4V 6.000V
0Hz ~ 1kHz 30V 1 60.00V
10Hz ~ 1kHz 60V 600.0V
Accuracy: 0.5%+4d
Max display: 9999 counts
Electrical Speciļ¬cations
Accuracy is Ā±(% reading digits + number of digits) or otherwise speciļ¬ed, at 23 Ā±5 & less than 75% R.H. True RMS Model ACD-15 ā„ƒ ā„ƒ
TRMS-PRO ACV & ACA clamp-on accuracies are speciļ¬ed from 5% to 100% of range or otherwise speciļ¬ed. Maximum Crest Factor are as
speciļ¬ed below, and with frequency spectrums, besides fundamentals, fall within the meter speciļ¬ed AC bandwidth for non-sinusoidal
waveforms.
Function Range Accuracy
www.Amprobe.com
Data Sheet
ACD-15 TRMS-PRO 2000A Digital Clamp-on Multimeters
Diode Tester
Open Circuit Voltage Test Current
< 1.6 VDC 0.4mA (typical)
Audible Threshold: between 0.015V & 0.080V
Capacitance
100.0nF 2), 1000nF, 3.5%+5d 1) 3)
10.00ĀµF, 100.0ĀµF, 2000ĀµF
1) Accuracies with ļ€lm capacitor or better
2) Accuracy below 50nF is not speciļ€ed
3) Speciļ€ed with battery voltage above 2.8V (approxmately half full battery). Accuracy decreases gradually to 12% at low
battery warning voltage of approximately 2.4V
Non-Contact EF-Detection
Typical Voltage Bar Graph Indication
15V TO 85V -
40V TO 130V - -
60V TO 210V - - -
90V TO 300V - - - -
ABOVE 120V - - - - -
Indication: Bar graph segments & audible beep tones proportional to the ļ€eld strength
Detection Frequency: 50/60Hz
Detection Antenna: Top side of the stationary jaw
Probe-Contact EF-Detection: For more precise indication of live wires, use the Red (+) probe for direct contact measurements
AC Current (Clamp-on)
50Hz / 60Hz 400.0A, 2000A 1.5% + 5d 1) 2) 3)
True RMS model ACD-15 TRMS PRO Crest Factor: < 2.0 : 1 at full scale & < 4.0 : 1 at half scale
1) Add 8d to speciļ€ed accuracy while reading is below 10% of range
2) Induced error from adjacent current-carrying conductor: < 0.06A/A
3) Speciļ€ed accuracy is for measurements made at the jaw center. When the conductor is not positioned at the jaw center, position er-
rors introduced are: Add 1% to speciļ€ed accuracy for measurements made within jaw marking lines (away from jaw opening) Add 4%
to speciļ€ed accuracy for measurements made beyond jaw marking lines (toward jaws opening)
Function Range Accuracy


Product specificaties

Merk: Amprobe
Categorie: Niet gecategoriseerd
Model: ACD-15 TRMS-PRO

Heb je hulp nodig?

Als je hulp nodig hebt met Amprobe ACD-15 TRMS-PRO stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Amprobe

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd