OWNER’S MANUAL
INSTRUCTIONS
INSTALLATION
OPERATION
MAINTENANCE
o ARRB-SERIES RADIANT BROILER
o ARTG-SERIES THERMOSTATIC GRIDDLE
o ARKB-SERIES KABOB BROILER
o ARHP-SERIES HOT PLATES
o ARSP-SERIES STOCK POT RANGE
o ACB-SERIES CHICKEN BROI LER
o ARCR-SERIES CHINESE WOK RANGES
MODEL NO.___________________________
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTHER
FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY
OR THIS OR ANY OTHER APPLIANCE.
WARNING
Improper installation, adjustment, alteration, service or
maintenance can cause property damage, injury or death.
Read the installation, operating and maintenance
instructions thoroughly before installing or servicing this
equipment.
Instructions to be followed in the event the user smells gas shall be posted in a prominent
location. This information shall be obtained by consulting the local gas supplier.
RETAIN THIS MANUAL FOR FUTURE REFERENCES.
This equipment is designed engineered for commercial use only.
AMERICAN RANGE CORPORATION
13592 Desmond Street • Pacoima, CA 91331
T: (888)753-9898 • F: (818)897 1670-
www.americanrange.com
A38077 07272015 13592 Desmond St., Pacoima, CA 91331 USA • www.americanrange.com - • T: (888)753 9898
Page 2 4 of
!
IMPORTANT
Installing, Operating and Service Personnel:
Installation of the equipment should be performed by qualified, certified, licensed and/or authorized personnel
who are familiar with and experienced in state/local installation codes.
Operation of the equipment should be performed by qualified or authorized personnel who have read this
manual and are familiar with the functions of the equipment.
Service of the equipment should be performed by qualified personnel who are knowledgeable with American
Ranges.
SHIPPING DAMAGE CLAIM PROCEDURE
The equipment is inspected & crafted carefully by skilled personnel before leaving factory. The transportation
company assumes full responsibility for safe delivery upon acceptance of this equipment. If shipment arrives
damaged:
1. Visible loss or damage: Note on freight bill or express delivery and have signed by the person making
delivery.
2. File claim for damages immediately: Regardless of the extent of damages.
3. Concealed loss or damage: If damage is noticed after unpacking, notify the transportation company
immediately and file ‘Concealed Damage’ claim with them. This should be done within fifteen (15) days
from the delivery date made to you. Retain container for inspection.
INSTALLATION INSTRUCTIONS
Gas pressure regulator provided with the equipment must be installed when the appliance is connected to gas
supply.
The area around the appliance must be kept free and clear of combustibles such as solvents, cleaning liquid,
broom, rags, etc.
Proper clearances must be provided at the front of the appliance for servicing and proper operation.
Provisions shall be incorporated in the design of the kitchen, to ensure adequate supply of fresh air and adequate
clearances for air openings into the combustion chamber, for proper combustion, and ventilation.
For proper operation of the appliance, do not obstruct the flow of combustion and ventilation air.
The installation must conform with local codes, or in the absence of local codes, with the national fuel gas code,
ANSI Z223.1 – 1988 (or latest addenda).
The appliance and its individual shut off valve must be disconnected from the gas supply piping system during any
pressure testing of that system in excess of 1/2 PSI.
A38077 07272015 13592 Desmond St., Pacoima, CA 91331 USA • www.americanrange.com - • T: (888)753 9898
Page 3 4 of
!
The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve
during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 PSI.
The gas supply line must be at least the same size as the gas inlet of the appliance.
Clearances
Non-combustible Walls
Combustible Walls
Rear
Sides
Rear
Sides
ARMG, ARTG, ARHP
0”
0”
7”
8”
A CB
0”
0”
4”
4”
ARRK, ARKB
0”
0”
16”
16”
ARSP, ARCR
0”
0”
N/A
N/A
For installation on a non-combustible counter/floor only.
OPERATING INSTRUCTIONS
Before lighting, check all joints in the gas supply line for leaks. DO NOT USE OPEN FLAME TO CHECK FOR
FLAMES! USE SOAP AND WATER SOLUTION.
Lighting and Shut Down
1. Turn all valves to “OFF” position.
2. Wait five minutes.
3. Turn pilot valve(s) adjusting – screw counter-clockwise, then light standing pilot and adjust flame1/4” inch
high.
4. Turn “ON” gas valve(s) to light main burners.
5. For complete shut down, shut off gas valve(s) and turn pilot valve(s) adjusting – screw clockwise to shut
off gas to the pilot(s).
Lighting and Shut Down (ACB Series)
1. Turn all valves to “OFF” position.
2. Wait five minutes.
3. Turn gas valve handle to pilot position. Depress the button and light pilot. Hold button for 30 to 40
seconds until the pilot stays lit.
4. If pilot goes out, repeat steps 1 – 3.
5. Turn “ON” gas valve(s) to light main burners.
6. For complete shut down, shut off gas valve.