Dear Customer: Please keep this warranty for your record. DO NOT return it.
913124160
One Year Limited Warranty
(5 years for Compressor Only)
Amcor, Inc. (“Amcor”) warrants the original retail purchaser (“Purchaser”) purchasing in the
United States that the Amcor product with which this warranty is enclosed is free from
defects in materials and workmanship.
Amcor’s sole obligation under this warranty is to replace, or at Amcor’s discretion, to repair,
free of charge, all defective parts, for a period of one (1) year from date of original purchase.
(5 years for Compressor Only) ANY IMPLIED WARRANTY OF MERCHANTABILITY IS
SIMILARLY LIMITED TO ONE (1) YEAR -(5 years for Compressor Only) FROM DATE OF
ORIGINAL PURCHASE AND NO ACTION BASED UPON ANY IMPLIED WARRANTY
OF MERCHANTABILITY OR OTHERWISE MAY BE COMMENCED AFTER EXPIRATION
OF ONE (1) YEAR -(5 years for Compressor Only) FROM DATE OF ORIGINAL RETAIL
PURCHASE. Some states do not allow limitations on how long an implied warranty lasts,
so the above limitation -(5 years for Compressor Only) may not apply to you.
The provisions of this warranty shall not apply to any product which in Amcor’s judgment
has been (1) subject to misuse or neglect. (2) damaged in an accident. (3) used for a purpose
for which it was not designed, or (4) repaired or altered in any way that adversely affected
its performance or reliability.
To obtain warranty service, the defective product or part must be shipped or delivered to:
Amcor’s authorized service center. All postage, insurance and shipping charges are the
responsibility of the Purchaser and are not included in this warranty.
AMCOR NEITHER ASSUMES NOR AUTHORIZES ANY PERSON TO ASSUME FOR IT ANY
OTHER ( LIABILITY IN CONNECTION WITH ITS PRODUCTS, THERE ARE NO
WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF.
NO RESPONSIBILITY IS ASSUMED FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES
THAT MAY RESULT FROM THE USE OF AN AMCOR PRODUCT, NOR FOR THE DAMAGES
DUE TO ACCIDENT, ABUSE, LACK OF RESPONSIBLE CARE, THE AFFIXING OF ANY
UNAUTHORIZED ATTACHMENT, LOSS OF PARTS, OR USE AT A VOLTAGE OTHER THAN
SPECIFIED. Some states do not allow the exclusion of limitation of incidental or consequential
damages, so these limitations may not apply to you.
Amcor disclaims all liabilities for defects or damages caused by use of replacement parts
obtained from or by service at any service center other than Amcor’s authorized service
center.
This warranty gives you specific legal rights, and you may also have other rights which vary
from state to state.
Product: AMCOR Plasma Portable Air Conditioner
Date Purchased:__________________________________ Production Code:________
QUESTIONS? Call 866-361-2233 · www.amcorgroupusa.com
14
It is important that
you read these
instructions before
using your new
purchase and we
strongly recommend
that you keep them
in a safe place for
future reference.
Owner’s
Manual
6/2006
www.amcorgroupusa.com
Portable Air Conditioner
For PLM models
Table of Contents
THANK YOU..............................................................................................................................1
Energy Saving Tips......................................................................................................................................................1
SPECIFICATIONS.......................................................................................................................2
BEFORE USE................................................................................................................................3
THE PLM UNIT / PARTS...........................................................................................................4
INSTALLATION OF THE WINDOW KIT...........................................................................5
Window Kit Installation.............................................................................................................................................5
INSTALLATION.........................................................................................................................6
OPERATION ..............................................................................................................................7
Turning the Unit On...................................................................................................................................................7
Setting the Clock.........................................................................................................................................................7
Setting the Temperature............................................................................................................................................7
Mode Button................................................................................................................................................................7
Fan Speed.....................................................................................................................................................................7
Heat Mode...................................................................................................................................................................7
To Set the Timer..........................................................................................................................................................8
Canceling the Timer Function..................................................................................................................................9
Sleep Mode..................................................................................................................................................................9
REMOTE CONTROL..............................................................................................................10
EMPTYING THE INTERNAL WATER CONTAINER ......................................................11
MAINTENANCE......................................................................................................................12
Cleaning the Unit.....................................................................................................................................................12
Cleaning the Filter....................................................................................................................................................12
End of Season Storage ...........................................................................................................................................12
TROUBLESHOOTING ...........................................................................................................13
WARRANTY.............................................................................................................................14
Troubleshooting
No power supply. Make sure outlet works.
Be sure Green Light is on (A.F.C.I. Plug)
Press Re-start button.
Is the LCD light flashing? Drain the Unit.
Timer Function Set. Deactivate the Timer Function.
Windows or doors Close doors and windows.
are open.
The filter is dirty. Clean or replace filter.
Air inlet or air Remove blockage.
outlet is blocked.
Room temperature lower Lower temperature selected.
than the selected value.
The overheat protection Wait 3 minutes until temperature
is activated. has decreased, then turn on again.
Unit is not standing Place on an even surface.
on a level surface.
Distance too great. Make sure the remote is aimed
at the control panel.
Remote control signal not Control is aimed at the
detected by control panel. control panel.
Batteries are dead. Replace the batteries.
If you have any questions regarding the operation of this PLM unit
please contact AMCOR at 1-866-361-2233
REPLACEMENT FILTERS:
To purchase Replacement Filters for this unit, contact AMCOR at
1-866-361-2233. Just provide the model number of your PLM unit.
If this product is defective or not working properly,
please DO NOT return to your retail store.
Please contact Amcor for service or technical assistance
Amcor Inc.
www.amcorgroupusa.com
The Unit is Noisy
The Air Conditioner
Does Not Function
Properly
The Remote
Control Does
Not Function
Problem Cause Solution
Never try to repair or dismantle the air conditioner yourself. Tampering with the unit
may result in the loss of warranty and can endanger the user and property.
13
The Unit
Does Nothing
Thank You!
Thank you for purchasing an AMCOR Portable Air Conditioner. AMCOR is a leading
brand in indoor air treatment. We would like you to enjoy the many benefits this
unit offers, so please read this manual carefully and take full advantage of the many
advanced features that your AMCOR Portable Air Conditioner offers you.
AMCOR has specialized in complete indoor environment control, manufacturing
world-class air conditioners, dehumidifiers and air purifiers with innovative technology.
In designing these advanced products, we have listened carefully to our customers
and have passed their views on to our research and development laboratories.
We wish you many years of enjoyable use.
After reading this manual, please keep it in a safe place for future reference.
Energy Saving Tips
• Do not locate the air conditioner where furniture or other objects can obstruct
the airflow.
• Keep doors closed so cool air does not escape.
• Keep the filters clean.
Set the unit to maximum cooling and high speed fan initially, then adjust the unit
to a comfortable setting.
NOTE: Use the Temperature Control (UP/DOWN) to adjust
Air Conditioner cooling to a desired level.
1
12
Maintenance
Always unplug the unit from the wall before performing any maintenance.
• Make sure the unit is drained before moving.
Cleaning the Unit:
• Only use a soft damp cloth.
• Never use chemicals, oil-based products, detergents, or other cleaning solutions.
These could damage the cabinet.
Cleaning the Filter:
• Slide out the filter holder
from the unit.
• Separate the filter fixer from
the filter holder (see fig. 1).
• Remove the active carbon filter (black) and slide out the 3M Filtrete™ filter (white).
• To clean filters, vacuum with standard vacuum cleaner.
• Insert the active carbon filter into the filter holder (see fig. 2).
• Insert the 3M Filtrete™ filter into the filter holder (see fig. 3).
• Fix the filters by reassembling the fixer into the filter holder (see fig. 4).
NOTE:
• Before storage be sure filters are clean and dry.
• Should you need to replace filters, contact Amcor for replacement.
• The screen filter must always be used.
• The 3M Filtrete™ Filter should be cleaned periodically. Both filters can be vacuumed.
IMPORTANT: NEVER operate the unit without a filter.
End of Season Storage:
• Unplug the unit.
• Drain the condensed water COMPLETELY.
• Clean the filter.


Product specificaties

Merk: Amcor
Categorie: Airco
Model: PLM12KE

Heb je hulp nodig?

Als je hulp nodig hebt met Amcor PLM12KE stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Airco Amcor

Amcor

Amcor FS7 Handleiding

15 Februari 2023
Amcor

Amcor PLM12KE Handleiding

27 Januari 2023
Amcor

Amcor AMC 12000 Handleiding

10 Januari 2023
Amcor

Amcor HW 12KE Handleiding

10 Januari 2023
Amcor

Amcor FS12 Handleiding

9 Januari 2023
Amcor

Amcor AF 8000E Handleiding

16 Oktober 2022
Amcor

Amcor AMC 10000 Handleiding

13 Oktober 2022

Handleiding Airco

Nieuwste handleidingen voor Airco