Adastra DP-8 Handleiding


Lees hieronder de đź“– handleiding in het Nederlandse voor Adastra DP-8 (7 pagina's) in de categorie Dimmer. Deze handleiding was nuttig voor 18 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/7
DP-8
DIGITAL POWER SCHEDULE CONTROLLER
Item ref: 058 953. UK
User Manual
Version 1.0
953.058 User Manual UK
Caution: Please read this manual carefully before operating
Damage caused by misuse is not covered by the warranty
Introducti on
Thank you for choosing an Adastra DP-8 digital power schedule controller for power automation of installed sound, lighting and service
equipment. This unit is designed to provide flexible scheduling and automation of 8 power outlets, fully programmable by the operator.
Please read this manual to gain the best results from your product and avoid damage through misuse.
SAFETY SYMBOL AND MESSAGE CONVENTIONS
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
AVIS
RISQUE DE CHOC ELECTRIQUE NE PAS
OUVRIR
This symbol indicates that dangerous voltage constituting a risk of electric shock is
present within this unit
This symbol indicates that there are important operating and maintenance instructions in
the literature accompanying this unit.
SAFETY NOTICE
1. Prior to use, read through this manual
2. Keep the manual in good condition
3. Pay attention to safety warnings
4. Observe all operating requirements
5. Do not use the device near water or wet areas
6. For cleaning, only use a lint-free, dry cloth
7. Install according to the specifications
8. Place away from heat sources or heating appliances
9. Use mains lead provided and avoid damage to cable or connectors
10. Unplug power from mains during stormy weather or if unused for long periods
11. In case of malfunction, water ingress or other damage, consult qualified service personnel
12. Do not place in damp areas or near liquids or moisture. Do not spill liquids on the housing
13. Please pay attention to warning symbols during transit and placement
14. Terminals marked with the symbol are HAZARDOUS LIVE and should only be connected by qualified personnel
15. Ensure that the apparatus is connected to a mains socket with a protective EARTH connection
16. Ensure correct operation of the mains switch
Note: This equipment is designed to be wired directl to mains power and should be installed by a qualified electrical engineer. y
The unit is hard-wired with a 36A mains cable.
If a domestic plug is connected to this, the rating may be reduced.
Warning
• To prevent the risk of fire or electric shock, do not expose any components to rain or moisture.
• If liquids are spilled on the casing, stop using immediately, allow unit to dry out and have checked by qualified personnel before
further use.
• Avoid impact, extreme pressure or heavy vibration to the case
• No user serviceable parts inside Do not open the case refer all servicing to qualified service personnel. – –
Placement
• This unit can be used free-standing or fixed into a 19” rack
• Ensure adequate support and access to controls and connectors when rack-mounting
Cleaning
• Use a soft cloth with a neutral detergent to clean the housing as required
• Do not use strong solvents for cleaning the unit
953.058 User Manual UK
Front panel
Rear panel
Setup and Current Capacity
Warning! the DP-8 and connected equipment must be isolated from the mains supply during the following setup.
The DP-8 is powered via a hard-wired mains cable via a circuit breaker rated at 32A.
This can be connected directly to the 110V or 230V mains power supply for maximum power capacity.
For low power applications, a standard mains plug may be used but the current will then be limited to any fuse fitted the plug. in
Note: Make all other connections before connecting power to the DP- 8.
Mains appliances can be powered from any of the 8 IEC power outlets (12) on the rear panel of the DP- 8.
Each of these is served by an electro-mechanical relay which is in turn controlled by the , DP-8 internal programming.
The DP- may not be suitable for powering from other equipment which may be sensitive to an inductive load, such as a inverter. 8 DC
The maximum total load at any time is governed by the main circuit breaker (1) or mains fuse if the DP-8 is powered from a UK plug.
The main circuit breaker is re-settable, but this is a safety device and should not be used to gauge the overall current throughput.
The DP-8 has built in alarms which can be set by the user to help avoid overloading.
Connect each appliance to one of the IEC outlets.
Make sure that the total current load will not exceed the fuse or breaker if all IEC outputs are activated at the same time.
If more than one single appliance is to be powered from any of the IEC outlets, a splitter or distribution block may be used, so long as
the combined load on the individual IEC outlet is less than 10A.
For very high-power configurations, any the IEC outputs can be used to remotely switch high current capacity 110V or 230V of er
contactors, which deliver the high current load to the appliances, using the DP-8 output just as a trigger with minimal current demand.
If all 8 channels are remotely triggering contactors, the DP-8 may be considered as a control device rather than a power distributor
and can easily be powered by a 13A UK plug.
When all IEC outlet connections are made, there are control signal options which should be connected if required.
A group of 6 plug-in screw terminals have connections for 12V remote control and RS485 connection.
A description of the 12V remote operation is detailed on the next page.
The RS485 connections are for future development
A USB connector is also provided for future development and for firmware upgrading.
1.
Main circuit breaker
6.
Numerical program / activate buttons
2.
Settings / Display button
7.
< and > buttons (previous/next page select)
3.
Enter / Timer enable button
8.
On/Off and +/- menu edit buttons
4.
Escape / Protect alarm button
9.
Clear / lock button
5.
LCD display
10.
USB connector
12.
IEC power outputs
11.
Remote control terminals
13.
Mains inlet cable


Product specificaties

Merk: Adastra
Categorie: Dimmer
Model: DP-8

Heb je hulp nodig?

Als je hulp nodig hebt met Adastra DP-8 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden